Glass-Filled ASA print settings

By Tony Tate · updated 2026-11-27 · First Layer 1.0.2

Glass-Filled ASA prints at about 265 °C with a 100 °C bed and 0% part cooling. Usable range 250–280 °C nozzle, 90–115 °C bed. Needs an enclosure. Abrasive — needs a hardened nozzle.

ASA-GFGF ASAGlass Fibre ASAGlass Fiber ASA

Starting settings

starting points Every number here is drawn from manufacturer data sheets across the material as a whole. None of it is a measurement of the spool in your hand, and brand-to-brand variation inside one material is wider than most people expect. Where a figure says "about", the app holds one typical value rather than a range. Treat all of it as somewhere to begin, then measure — shrinkage and flow especially, because those two are what throw dimensions off.

Nozzle
250–280 °C (start 265)
Bed
90–115 °C (start 100)
Part fan
0–20% (start 0%)
Wall speed
25–45 mm/s
Max volumetric flow
about 9 mm³/s
Shrinkage
about 0.35%
Softens at
about 105 °C
Enclosure
Required
Nozzle size
0.4 mm or larger — 0.6 mm recommended
Nozzle material
Hardened steel required — this is abrasive
Drying
about 70 °C for 4 h

Speed

Same as glass-filled ABS, 25–45 mm/s.

Bed surface

Smooth PEI at 100 °C inside an enclosure.

Nozzle

Hardened steel, 0.6 mm preferred.

What bites people

Safety

Common questions

What temperature should I print Glass-Filled ASA at?

Start at 265 °C nozzle and 100 °C bed, within a usable range of 250–280 °C and 90–115 °C. Run a temperature tower on your own spool rather than trusting any table: brand-to-brand variation inside one material is wider than most beginners expect.

Does Glass-Filled ASA need an enclosure?

Yes. Glass-Filled ASA warps and splits without one.

What nozzle do I need for Glass-Filled ASA?

0.4 mm or larger, with 0.6 mm recommended. It is abrasive, so it needs a hardened steel nozzle — it will wear a brass one wider as you print, which quietly invalidates every calibration you have done.

Open First Layer →
The app walks this in order, generates the test model for your nozzle and filament, and records what you measure so nothing has to be repeated. Free, no account, works offline.